Space

Sunday, 10 February 2019

RAW MIX TO CLINKER FACTOR- Dust to Silo

 RAW MIX TO CLINKER RATIO - DUST TO SILO

You can calculate the raw mix to clinker factor by using following input data:
1. Loss on ignition of raw mix
2. Ash absorption
3. dust losses in preheater



Raw Mix to Clinker Ratio- Dust to Silo
Input Data:
1 LOI of raw Mix in % LOI
2 Ash Absorption in % Ash
3 Dust Losses from preheater in % DL
Formula:
Rawmix to clinker Ratio - Dust to Silo
( 100 - %AA ) * 100
( 100 - LOI ) * ( 100 - DL )
RAWMIX TO CLINKER RATIO - DUST TO SILO
INPUT
SN DESCRIPTION UNIT VALUE
1 LOI of Raw Mix %
2 Ash Absorption %
3 Dust Losses From Preheater %
OUTPUT
RESULT
RAWMIX TO CLINKER RATIO - DUST TO SILO Kg rawmix/kg clinker
Target